Problem: In Windows 7 (64bit) it is possible that you've created System DSN ODBC connections but they are not listed in the Datasource drop-down in the EnergyCAP login screen. Solution: Since your Windows 7 machine is 64-bit based, by default the ODBC administrator that's linked through the start menu is the older 32-bit version that doesn't play entirely well with the 64-bit registry. Instead, you have to run a modified version of the 32-bit ODBC Administrator from another folder. Why Microsoft did this since the system knows it's a 64-bit system is beyond our comprehension! So, to correct the problem, please LOGIN AS A SYSTEM ADMINISTRATOR and follow these steps: Using Windows Explorer, go to the folder: %systemroot%\Windows\SysWoW64 Which likely translates to: c:\Windows\SysWoW64. Run the application: odbcad32.exe Re-setup your System DSN ODBC Datasource and all should be OK. Written 4/16/2010 by Ryan Ohlson with information from Ryan Booz | |
|